DINGDANG INDUSTRY CO.,LIMITED
|
Price: | 0.8~10.0 USD |
Payment Terms: | T/T,L/C |
Place of Origin: | Zhejiang, China (Mainland) |
Add to My Favorites | |
HiSupplier Escrow |
HDPE Ground Source Heat Pump Five Ways Pipe Fitting
Ground source heat pump system is environmentally friendly use of shallow geothermal energy
utilization systems capable of heating and cooling energy use of new technologies. Ground source heat
pump systems are usually transferred underground soil heat or cold to where it is needed, but also take
advantage of the huge underground heat storage in soil storage capacity, winter ground source heat
transferred from the soil to the ground inside the building, then summer cold underground transferred
to the building, an annual form a thermal cycling system to achieve energy saving features.
***Principle
Ground source heat pump is a new use of shallow geothermal energy technology capable of heating and
cooling,the heat pump uses the principle of reverse Carnot cycle cooling and heat transfer equipment.
Ground source heat pumps can usually refers to the transfer of heat or cold underground soil volume
to where it is needed,usually used as air conditioning, refrigeration or heating use. Ground source heat pump also uses regenerativehuge underground storage capacity of the soil in winter the heat
is transferred from the soil to the ground inside the building cool in summer and then transfer
the amount to the inside of the building underground, just different winter and summer working
temperature range only.
1. Cooling mode
In the cooling state , the ground source heat pump compressor for refrigerant acting to be
vapor - liquid conversion cycle. Circulating through the evaporator fan coil evaporator by the
refrigerant to absorb the heat carried by the refrigerant , and then through the condenser condensing
the refrigerant from the refrigerant circulating water entrained in the refrigerant cycle to absorb heat,
water is transferred fromthe final cycle to ground water, groundwater or soil. Continuously transferred
to the indoor heat underground process through fan coil units, in the form of cold below 13 ℃ for
room cooling .
2. Heating mode
In the heating state, the refrigerant acting on the compressor and the refrigerant flow direction
through the valve commutation. Absorption by water circulating underground surface water, groundwater
or soil heat by evaporation of refrigerant in the condenser , the water circulating in the
refrigerant to absorb heat , while the refrigerant circulating through the refrigerant within the
evaporator condensate from Fan coilloop carried by the refrigerant heat absorption . Heat is
continuously transferred to the ground in the process chamber in the form of hot air to above 35 ℃
indoor heating .
***Specifications of HDPE Siphon Five Ways Pipe Fittings:
Size | MOQ |
Dn40x32 | 500pcs |
Dn50x32 | 500pcs |
Dn63x32 | 500pcs |
Dn75x32 | 500pcs |
Dn90x32 | 500pcs |